System Commands
Copyright © Itech Electronic Co., Ltd. 14
Parameters
0~30
Query syntax
SYSTem:COMMunicate:GPIB:RDEVice:ADDRess?
Returns
0~30
SYSTem:INTerface
This command is used to switch the communication interface. IT7321 does not
support GPIB interface.
Command syntax
SYSTem:INTerface <USB|RS232|LAN|GPIB>
SYStem:PRESet
System reservation command
STATus:QUEStionable[:EVENt]?
This command can be used to read the value in query event register.The power
supply will return a decimal number corresponding to the binary weighted sum
of each unit digit of register. These digits will be latched. After executing this
command, the query event register will be cleared.
Query syntax
STATus:QUEStionable[:EVENt]?
Parameters
None
Returns
<NR1>
Related commands
STATus:QUEStionable:ENABle
STATus:QUEStionable:CONDition?
This command is used to read the value of query condition register to get the
power meters status, such as ocpeak/ ocrms/ ov/op/ot.