Phase Control Commands
Copyright © Itech Electronic Co., Ltd. 25
Chapter5 Phase Control Commands
[SOURce:]PHASe:STARt
This command is used to set the starting phase angle of the power supply.
Command syntax
[SOURce:]PHASe:STARt
Parameters
MINimum|MAXimum|DEFault|Float
Example
phas:star 80
Query syntax
[SOURce:]PHASe:STARt?
[SOURce:]PHASe:END
This command is used to set the termination phase angle of the power supply.
Command syntax
[SOURce:]PHASe:END
Parameters
MINimum|MAXimum|DEFault|Float
Example
phas:end 80
Query syntax
[SOURce:]PHASe:END?
[SOURce:]DIMMer[:PHASe]
This command is used to set the phase angle of the phase dimming function.
Command syntax
[SOURce:]DIMMer[:PHASe]
Parameters
MINimum|MAXimum|DEFault|Float

Table of Contents