IEEE488.2 Common Commands
Copyright © Itech Electronic Co., Ltd. 59
Related commands
*RCL
*RCL
This command can recall the setups you saved before from the specified
memory.
Command syntax
*RCL<NRf>
Parameters
0~9
Example
*RCL 3
Related commands
*SAV
*WAI
This command instructs the power supply not to process any further commands
until all pending operations are completed.Pending operations are as defined
under the *OPC command.*WAI can be aborted only by sending the power
supply a device clear command.
Command syntax
*WAI
Parameters
None
Related commands
*OPC
*TST?
This command is used to query the self-test by the instrument. 0 indicates that
self-test succeeds; other Arguments indicate self-test fails. In addition, in case
of failure, an error information will be generated to describe failure reason.
Query syntax
*TST?