EasyManuals Logo

ITech IT7324 Programming Guide

ITech IT7324
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
Maximum Power Point Scanning Commands
Copyright © Itech Electronic Co., Ltd. 46
Chapter11 Maximum Power Point Scanning
Commands
SWEep:STATe
This command is used to set the scan function status.
Command syntax
SWEep:STATe
Parameters
DISable|ENABle
Example
SWEep:STATe ENAB
Query syntax
SWEep:STATe?
SWEep:RECall
This command is used to invoke the scan file.
Command syntax
SWEep:RECall <NR1>
Parameters
0~9
Example
SWEep:REC 4
SWEep:STARt:VOLTage
This command is used to set the start voltage of the scan function.
Command syntax
SWEep:STARt:VOLTage <NR1>
Parameters
MINimum|MAXimum|Float

Table of Contents

Other manuals for ITech IT7324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7324 and is the answer not in the manual?

ITech IT7324 Specifications

General IconGeneral
BrandITech
ModelIT7324
CategoryPower Supply
LanguageEnglish

Related product manuals