Technical Specifications
Copyright ©ITECH Electronic Co., Ltd. 82
*2
: FS=full scale: Vrms=300Vac, Irms=24A; Ipk=72A; P=3000VA.
*3
: The minimum voltage of THD test is 10Vac (Auto mode) and 20Vac (High
mode).
The maximum distortion test is carried out by outputting the maximum current
to linear load under 125Vac (Auto mode) and 250Vac (300V mode).
*4
: The test frequency accuracy should ensure that the minimum voltage is
30Vac.
*5
: Testing premise is in Fast mode
*6
: The minimum voltage setting must not be less than 50Vdc.
*7
: FS=full scale: Vdc=424Vdc; Idc=12A; P=1500W.
Parameter IT7627 V1.3
AC Input
Voltage
380Vac±10%(Y)
Phase
3ø
Frequency
10-5kHz
Max.Current
60A
Power Factor
0.7(typical)
AC Output
Output phase
1φ or 3φ
Max.output power
9KVA
Max.output power of each phase
3KVA
Voltage range
2V-300V, 1V-150V/2V-300V Auto
Voltage resolution
10mV
Voltage accuracy
*1
±0.2%+(0.2%+0.2%×Kfreq)×FS
*2
Temp. coefficient ±(0.04% per degree from 25°C)
Max.Current
(1φ)
RMS 72A/36A
*8
Peak(CF=3) 216A/108A
*8
Max.Current
(3φ)
RMS 24A/12A
Peak(CF=3) 72A/36A
Total Harmonic Distortion(T.H.D)
*3
≤0.5% at 10-500Hz (Resistive Load)
≤2% at 501-5000Hz (Resistive Load)
Crest Factor
3
Line Regulation
≤0.1%FS(Resistive Load)
Load Regulation
≤0.5%FS(Resistive Load)
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com