Technical Specifications
Copyright ©ITECH Electronic Co., Ltd. 83
Dynamic response time
≤200us(typical)
DC Output
Max.output power
4.5KW
Voltage output
±200V/±400V
*6
Voltage resolution
10mV
Voltage output and readback
accuracy
±(0.2%+0.2%FS)
*7
Temp. coefficient ±(0.04% per degree from 25°C)
Current range
36A/18A
Current resolution
10mA
Readback accuracy current
±(0.3%+0.3%FS)
*7
Power meter accuracy
±(0.4%+0.4%FS)
*7
Voltage ripple
Peak 500mVp-p
Rms
200mVrms
Meter
AC Voltage
Range
0-300Vac
Resolution
10mV
Accuracy
±(0.2%+0.2%FS)
Temp.
coefficient
±(0.04% per degree from 25°C)
AC
Current(rms)
Range
0-72Arms
Resolution
10mA
Accuracy
±0.3%+(0.3%+0.2%×Kfreq)×FS
*2
Temp.
coefficient
±(0.04% per degree from 25°C)
AC
Current(peak)
Range
0-216Apeak
Resolution
10mA
Accuracy
±0.3%+(0.3%+0.2%×Kfreq)×FS
*2
Temp.
coefficient
±(0.04% per degree from 25°C)
Power
Resolution
10mW
Accuracy
±0.4%+(0.4%+0.2%×Kfreq)×FS
*2
Temp.
coefficient
±(0.04% per degree from 25°C)
Phase Angle Range 0-360°
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for ITech IT7622

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7622 and is the answer not in the manual?

ITech IT7622 Specifications

General IconGeneral
BrandITech
ModelIT7622
CategoryPower Supply
LanguageEnglish

Related product manuals