Remote module wire color
Brown Gray Yellow
Register manufacturer Register screw color designator
Badger RTR (3-wire) Red Black Green
Badger RTR (2-wire) Red Black No connection*
Badger M5000 Mag Meter Red terminal: Out 1+ Black terminal: Out 1- White terminal: Out 1+
■
Cadillac Meter CMAG/EMAG
■
Magnetic Flow
DO1/DO2 COM COM
Elster Digital Black Green Red
Elster V100T Red &Black Blue Yellow
■
Itron (Actaris)
■
Flostar (2-wire)
■
Cyble Sensor
Either wire Remaining wire must be connected to both
ERT Module wires
Krohne IFC Term B Term H Term B
RG3 Tomahawk Green Black Green
Sensus PMM Red Black Bare
Note: *Itron recommends terminating unconnected wires with a gel-cap connector to protect the bare wire
end. See for more information.
Extending the Cable
Order the 25-foot inline connector extension cable assembly (CFG-0151-404) to extend
the 500WERTModule's cable.
Verifying Operation
Use one of the following programming devices to verify that the 500WERTModule is
correctly recording consumption data.
■
FC300SR handheld computer
■
Itron Mobile Radio connected to a user-supplied computer or Bluetooth device
Caution: Verifying the 500WERTModule operation requires an FC300SR handheld computer or
Itron Mobile Radio running FDM 4.0 or later. Legacy Itron handheld programming devices cannot
read the 500WERTModule .
Gen5 500WERTModule Remote Installation Guide 2 Initializing and Connecting
December 5, 2022 LDI-0343 REV002 Itron, Inc. Page 15 of 48