Troubleshooting
This information is provided to help you troubleshoot issues related to
500WERTModules.
The following table describes possible issues and provides suggested actions to resolve
the issue.
Issue Action
Cannot program the 500WERTModule. Check the programming device and software version.
Program 500WERTModule using the FC300
handheld computer running Field Deployment
Manager (FDM) software v4.0 or higher.
Cannot read the 500WERTModule. A 500WERTModule that is not programmed will not
transmit an SCM+ message. Reprogram the
500WERTModule and perform a reread. If a
500WERTModule is not initially programmed, it will
not bubble-up and listen for an SCM+ message.
The 500WERTModule is reporting an invalid read. A 500WERTModule that has set the Register Error
flag will cause an Invalid Read to display in the FDM
Consumption field.
Marginal readability due to 500WERTModule location
(for example, a 500WERTModule deep inside a pit).
Consider reprogramming the 500WERTModule for
Hard-to-read (H2R) mode. Programming the
500WERTModule for hard-to-read mode increases
the output to high power.
Note: Hard-to-read mode will reduce battery life.
The handheld programmer is locked up and button
presses produce no response.
Soft boot the handheld. Reference the documentation
for your programming device. For more information,
see Related Documents on page 7.