Mounting Accessories
Accessory Part number
Remote mount kit (500WERTModule with telemetry device) CFG-1300-003
Pipe mount kits
Pipe mount kit for pipe diameters up to 4” CFG-0217-501
Pipe mount kit for pipe diameters between 3/4” to 1-3/4” CFG-0217-503
Pipe mount kit for pipe diameters between 1-5/16” to 2 ¼” CFG-0217-504
Cable armor (for field retrofit installation instructions, )
5-foot cable thin-insulation (with protective cover and cable armor) CFG-0151-006SS
5-foot cable thick-insulation (with protective cover and cable armor) CFG-0151-010SS
5-foot cable armor for field retrofit FAB-1302-001
Direct mount screw pack SCR-0010-005
Direct mount screw pack, bulk: 80 per bag SCR-0010-004
Direct mount screw pack, bulk: 122 per bag SCR-0010-001
Direct-mounting to the Meter Register
Direct-mounting 500WERTModules to a meter register requires a register designed for
that purpose. This section describes 500WERTModule installation for the following direct
mount registers:
■
Badger ADE and RTR
■
Elster/AMCO (ABB) Scancoder, InVISION, and Digital
Warning! Do not use the direct mounting method in a pit environment. Use a 500WERTModule
for pit environments.
Direct mounting on the ABB Scancoder, InVision, or Digital Direct Mount
Note: Verify that you have an Elster/AMCO meter with a register designed for direct-mount
500WERTModule. Always install the 500WERTModule right side up with the arrow on the housing
pointed upward. The register may or may not be mounted on the meter when performing the following
steps.
Gen5 500WERTModule Remote Installation Guide 3 Setting up and Installing
December 5, 2022 LDI-0343 REV002 Itron, Inc. Page 21 of 48