Note: A gasket is not required.
5. Install four Torx-head mounting screws (SCR-0010-005) and hand-tighten the screws.
6. If you have not already done so, connect the register to the water meter and fully tighten
the mounting screw (1) as directed by Badger Meter.
Note: Mount the register on the meter in one of four different positions with respect to the direction of
water flow (refer to the manufacturer's installation directions).
7. If the standard Torx screw is used (1), a wire seal is not necessary. If the optional slotted
and drilled RTR screw is used, install a wire seal through the drilled screw from (1) to (2),
or as specified by utility policy.
Mounting to a Pipe
The 500WERTModule can mount on a pipe vertically, diagonally, or horizontally using a
pipe mount kit and remote mount kit (see Mounting Accessories on page 21).
Gen5 500WERTModule Remote Installation Guide 3 Setting up and Installing
December 5, 2022 LDI-0343 REV002 Itron, Inc. Page 25 of 48