EasyManua.ls Logo

ITRON Gen 5 500W ERT - Using Gel-cap Connections for Wiring; Crimping the Connector

ITRON Gen 5 500W ERT
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Using Gel-cap Connections to Complete Wiring
Connections
Important! All unused wires on 500WERTModule must be terminated. Wire terminations must be
properly sealed with a non-conductive gel material to prevent water intrusion and possible
environmental or electrical issues.
This section provides the instructions to complete remote module to meter wiring
connections. Gel-cap connections require:
E-9R 3M
®
gel connector crimping tool (or other 3M approved crimping tool)
Itron splice kit (part number OEM-0034-002)
1. Push two wires as far as possible into the connector.
Caution: Do not strip insulation from the ends of the wires before inserting them into the
connector.
2. Place the connector and wires into the jaws of the crimping tool. Ensure the wires remain
fully inserted in the connector.
3. Squeeze the handles to crimp the connector. Apply pressure until the cap is fully seated
(at least three seconds).
December 5, 2022 LDI-0343 REV002 Itron, Inc. Page 34 of 48