Events and Alarms
The following table describes events and alarms for the 500WERTModules. These
events and alarms are supported only when the device is in network mode.
Event ID Event name Event description
1 Inter Digit Corrupt digit in the encoded register reading.
2 Register Error No Communication with Register.
3 Invalid Read Register is not sending a valid read.
6 Endpoint - Low
Battery
500WERTModule has a low battery warning. 10% battery life remaining.
Is an alarm by default.
7 Consumer Leak
detected
500WERTModule has detected continuous flow over a set period of time.
Is an alarm by default.
Qualifies as an active event.
8 Consumer Leak
end
500WERTModule has detected the end of continuous flow after having reported a
leak.
9 Reverse Flow
detected
500WERTModule has detected reverse flow.
Qualifies as an active event.
10 Reverse Flow end 500WERTModule has detected the end of reverse flow after having reported reverse
flow.
11 Leak Sensor Ok 500WERTModule detects a leak sensor attached and it is working properly (triggered
when state was previously unknown or previously not working properly).
12 Leak Sensor No
Comms
500WERTModule detects a leak sensor is attached but it not working properly.
13 Leak Sensor
Detached
500WERTModule does not detect a Leak Sensor attached after having previously
having one attached.
14 Valve OK 500WERTModule detects a disconnect valve attached and it is working properly
(triggered when state was previously unknown or previously not working properly).
15 Valve No Comms 500WERTModule detects a disconnect valve is attached but it not working properly.
17 Pulse Mismatch The 500WERTModule has detected an internal pulse mismatch.
18 Cut Cable
detected
Physical Cut Cable detected by the 500WERTModule.
Qualifies as an active event.