Note: A tamper seal is fully seated when the top of the tamper seal is approximately 1/16 inch below the
top of the screw recess.
7. Secure any excess cable using the provided cable ties.
Installing the Remote Disconnect Valve
This section describes installation of a Smart Earth Technologies (SET) Remote
Disconnect Valve in a water system. The 500WERTModule automatically detects the
presence of connected water disconnect devices within 22.5 minutes and begins reading
disconnect valve data. To immediately detect the water disconnect valve and begin
reading data, perform a Check ERT with a handheld computer running FDM software.
The 500WERTModule supports the following states:
■
Connected. The water flow is open and flowing at 100% configured capacity.
■
Disconnected. The water flow is shut off with no water flowing. The remote water
disconnect valve provides the ability to remotely open (reconnect) the valve.
■
Restricted. The water is restricted and flowing at the configured installation flow.
Wire Connections
Connect the 500WERTModule wires to the Remote Disconnect Valve wires following the
connections shown in the table below. The Remote Disconnect Valve connects to the
Cellular 500W orange, white/purple, and blue wires.
Connect the 500WERTModule wires to the SET valve wires following the connections
shown in the SET Valve/500WERTModule wire connections table.
500WERTModule wire color Remote Disconnect Valve wire color
Orange Red
White/purple Black
Blue Green
Gen5 500WERTModule Remote Installation Guide 3 Setting up and Installing
December 5, 2022 LDI-0343 REV002 Itron, Inc. Page 30 of 48