Note: Interval data configuration is dependent on the module's firmware version. See Firmware
Functionality on page 11 for more information.
The 500WERTModule also sends a local access beacon message every 60 seconds that
allows users to gather contingency readings locally when needed.
Caution: If you perform a switch to network mode or switch to mobile mode operation, it results in
a loss of interval data.
The 500WERTModule operates using the 902 to 928 MHz in the ISM band frequency
band and does not require an FCC license.
Mobile Mode
In mobile mode, the module transmits every nine seconds over multiple RF channels to
report on:
■
meter register value
■
cut cable or communication error event
■
reverse flow (encoder version selected)
■
system leak status
■
low battery indicator
Operating Modes
The 500WERTModule has the following operating modes.
■
Factory mode
–
500WERTModules are shipped from the factory in factory mode.
–
The 500WERTModule's transmitter is turned off.
–
The 500WERTModule's receiver is bubbling up to listen for a programming
command.
–
500WERTModule attempt to read the register every hour.
–
Register Error Detected and Register Error alarm or event flags may be set when a
register is not connected.
–
If the 500WERTModule reads a connected register, the module automatically moves
to run mode.
■
Audit mode
–
Audit mode reduces the normal read latency time associated with standard modes of
operation and is often used after initial installation.