1. Remove the installed 500WERTModule.
Note: Itron strongly recommends that you keep the 500WERTModule connected to the register during
cable armor installation.
2. Cut a two- to three-inch strip of electrical tape.
3. Wrap the entire piece of electrical tape around the 500WERTModule cable near the
500WERTModule .
4. Beginning over the installed electrical tape, twist the Itron cable armor onto the
500WERTModule cable using a right-handed twist.
Warning!You must twist—not wrap—the cable armor onto the 500WERTModule cable.
Wrapping the cable armor can cause the stainless steel jacket to warp.
You must begin twisting the cable armor over portion of the cable protected by the electrical tape. If
you do twist the cable armor onto the 500WERTModule cable on the unprotected portion of the
500WERTModule cable, you could damage the module's cable. A cut cable could cause an
500WERTModule or register communication failure.
5. Continue to twist the cable armor onto the 500WERTModule cable until the cable armor
covers the entire cable.
Gen5 500WERTModule Remote Installation Guide 3 Setting up and Installing
December 5, 2022 LDI-0343 REV002 Itron, Inc. Page 32 of 48