EasyManua.ls Logo

ITRON SL7000 IEC7 - Page 70

ITRON SL7000 IEC7
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User G
uide SL7000 IEC7
68
The annunciator icon indicators represent the following:
Icon Name Description
Battery status Indicates when the measured battery voltage is lower than the
programmed threshold, or the cumulative power failure duration
exceeds three years.
Alarm Indicates when the meter has detected an active alarm condition.
Excess demand Indicates when the calculated demand value is higher than the
programmed threshold.
Communication Indicates that there is active communication in progress between the
meter and an external device.
Phase Each of the three icons represent a connected phase.
If a phase is missing, the associated icon is not lit.
If voltage sags or swells occur on a phase, the associated icon will
blink.
Quadrant The four individual arrow icons indicate the direction and type of the
energy currently measured by the meter.
Active and Reactive
Import and Export
If the incoming supply phase-sequence is incorrect (e.g. 1,3,2) these
icons flash.
The following examples show the effect meter configuration parameters such as scaler, number of digits and
decimal places, have on the display.
Example 1
The energy channel configured in Wh and the value is 123 456 789 Wh.
Depending on the scaler value the reading via COSEM read out would be:
123456789*Wh
123456,789*kWh
Scaler Decimal Digits Displayed value Unit Format Max display value
1 0 6 456789 Wh 6+0 999 999 Wh
10³ (10 E 3) 1 6 23456,7 kWh 5+1 999 99,9 kWh
10³ (10 E 3) 2 6 3456,78 kWh 4+2 9 999,99 kWh
1 0 7 3456789 Wh 7+0 9 999 999 Wh
10³ (10 E 3) 1 7 123456,7 kWh 6+1 999 999,9 kWh
10³ (10 E 3) 2 7 23456,78 kWh 5+2 99 999,99 kWh

Table of Contents