EasyManua.ls Logo

Iveco WAY RANGE - Battery Disconnect Switch

Iveco WAY RANGE
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
Manual battery disconnect switch
When the vehicle is shut down for a long period of time (> 12 hours), disconnect the electrical system from the batteries by turning the
battery disconnect switch anti-clockwise by 90°. To restore the electrical connection, turn the battery disconnect switch back.
Automatic battery switch
The battery disconnect switch (1) automatically activates when a key is inserted into the slot after a time defined by the user, and disconnects
the batteries from the vehicle's circuits.
The connection is automatically restored in the following cases:
1. Switch on the remote main power switch by pressing the (1) button.
2. Switching command to immediately activate the auxiliary water heater
3. Switch on a light in the driver’s cab
4. Switch on the hazard flashers
5. Activate the horn
6. Open the driver’s or passenger’s side door
7. Switch on the exterior lighting (parking light)
8. Door unlocking
9. Press one of the three buttons on the remote control for the central locking system
10. Activate lowering of the cab
11. Activate the bed module
12. Activate the electric roof hatch
13. Activate the temperature controller to the “MAX” (85%) position for a manual air conditioning system.
After automatic closing, the electric battery disconnect switch can be deactivated again automatically if the following conditions are fulfilled at
the same time: 1. All functions for the previously described requirements for automatic activation are no longer active. The push button
function (1) is blocked for the first 10 s after shutting down the motor (when the electronic key is inserted in the slot) if the auxiliary heating
is not switched on. If the auxiliary heating is switched on, it must be switched off and the pushbutton (1) must be pressed, then the user must
wait to the end of the cleaning cycle for the heating device (approx . 3 min).
BATTERY DISCONNECT SWITCH
WARNING: When the button is pressed (1), the supply to
some equipment on board the vehicle is interrupted, and
the AdBlue® system is not emptied correctly. This
procedure can cause DAMAGE, and may be used only in
emergency situations. The function of the system must be
restored as soon as conditions allow. Wait 2 minutes after
turning off the engine before power is shut off to the
engine, or the batteries are disconnected. Failure to do so
could result in damage to the AdBlue® system. Press the
(1) button once again to restore the supply to the electrical
system.