Page #51 background imageLoading...
Page #51 background image
Maintenance Manual for J2 Sedan
Mechanical Part of Engine
50
Caution:
Perform
this
operation
after
the
exhaust
system
has
completely
cooled
down.
Disconnect the
wire ha
rness connectors of front
oxygen sensor. Special tools should be used if
necessary.
Tightening
torque:
30-40
m
Attention:
Do
not
damage
the
oxygen
sensor.
It is forbidden to use any oxygen
sensor
which ha
s dropped to
the hard
ground from
a heig
ht
above 0.5m. Such an
oxygen sensor should be replaced.
Unscrew the
fixing bolt for heat shield of exhaust
manifold, and then take off heat shield.
Tightening
torque:
9-11m
Unscrew bracket
bolt
to
remove
the
exhaust
manifold
bracket.
Tightening
torque:
20-25 N·m
Unscrew
fixing
bolt
to remove
the
exhaust
manifold.
Tightening
torque:
M8 35±2
m
Fig. 1.1.020
Fig. 1.1.019
Fig. 1.1.021
Fig. 1.1.022