English
Should the problem persist, please contact your technician.
11.2 Machines without a
screen
Flashes or code displayed on
screen
Cut-out SECU1 tripped during cycle.
Please restart the
machine using the
emergency stop (fig.1,
n°5). Should the problem
persist, please contact
your technician.
Current to upper actuator (M2) in excess of
6 A for 1 second, during advance/cut.
Cut motor thermal cut-out (F3) tripped.
No actuator (M2) movement despite tension set
to maximum.
Loaf pusher not in initial position. Limit switch S1
not tripped.
Advance/cut cycle time in excess of 60 seconds.
Return cycle time in excess of 30 seconds.
Rear (S1) and front (S2) limit switches tripped at
the same time.
Current to upper actuator (M2) in excess of 5 A
for 1 second during carriage return.
Front safety cover (S3) open in the course of a
cycle.