19
MENU CONSTRUCTEUR
The machine is completely stopped
Did you plug it in?
Is the power supply coming to the socket?
Is the disconnector switched on?
Is the front cover properly closed?
4th line displays "VARIATOR FAULT"
Is the thermal relay switched on?
Is there an alarm on the variator?
4th line displays "COOLING FAULT"
Disconnect the machine and contact your dealer.
Dashes appear instead of time « - - : - - : - - ».
Call your dealer. Internal clock is faulty.
Dashes appear instead of vat temperature « - -° »
Call your dealer. Probe is faulty
Always get an authorised agent to carry out maintenance work on your machine!
TROUBLESHOOTING
When ordering spare parts, check with your authorised agent the parts concerned using
the spare parts catalogue published by the manufacturer.
Always provide the machine number as indicated on the rating plate.
Your agent will order the parts from JAC.
SPARE PARTS
DISPLAY VALUE UNIT DESCRIPTION
VALUE
RANGES
P24 BUZZER 5 Sec. Buzzer period before warning 5 - 250
P25 BUZZER R 60 Sec. Cooling buzzer duration 5 - 250
P26 BUZZER NB 30 Min. Low level buzzer duration 2 - 30
BUZZER NH Not used
P27 STOP AGITATION NON Stop agitation if cold request NO / YES
P28
MINIMUM PRESERVA-
TION
10 °C / °F
Minimum preservation setting if agitation
stop
4 - 20 / 40 - 70
NO MATURATION
Not used
NO PRESERVATION
Not used