SECTION 4: TROUBLESHOOTING SECTION
COMMON PROBLEMS
WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified ser-
vice technician. Many of the tests require that the unit have power to it and live electrical components be
exposed. USE EXTREME CAUTION WHEN TESTING THE MACHINE.
Problem: Water temperature is less than required.
1. Low incoming water temperature. Compare to data plate.
2. No power to heater. Check wiring, replace if necessary.
3. Thermostat out of adjustment. Adjust or replace thermostat as required.
200 Series Technical Manual
7610-100-45-00 Rev. E (02/10/2006)