2
07610-004-04-18-R
AVENGER HT-E
Operating Capacity:
Racks per Hour 26
Dishes per Hour 468
Glasses per Hour 936
Tank Capacity (Gallons):
Wash Tank 3
Rinse Tank 2.12
Electrical Loads (as applicable):
Wash Motor HP 0.75
Wash Heater KW 4
Rinse Heater KW 4
NOTE: Always refer to the machine data plate for specic electrical and water
requirements. The material provided on this page is for reference only and is
subject to change without notice.
Water Temperatures (Fahrenheit):
Minimum Wash Temperature 155
Minimum Rinse Temperature 180
Minimum Incoming Water Temperature 110
Other Water Requirements:
Water Flow Pressure (PSI) 10
Flow Rate Minimum (GPM) 5.16
Water Line Size (NPT) 1/2"
Drain Line Size (NPT) 1" ID
1 3/8" OD
OPERATING PARAMETERS
SPECIFICATIONS