1. The Jacuzzi® Swim Spas are class "1" appliances and therefore they must be permanently
connected, without any intermediate connecons, to the electrical system and to the
protecon system (earth system)."
2. The power supplied to this swim spa must be a dedicated circuit with no other
appliances or lights sharing the power provided by the circuit.
3. The installer must use cables with a suitable cross-secon.
4. For connecon to the power supply network, we recommend installing an isolang
mul-pole switch, which will ensure complete disconnecon in the event of a
category III over-voltage; these devices must be posioned in an area that complies with
the safety regulaons.
5. The electrical system of the building must be provided with a 0.03A differenal switch
and with an efficient protecon (earth) circuit. Check for proper operaon of the
differenal switch by pressing the TEST buon, which should trip.
6. The electrical circuit supplied for the swim spa must include a suitable ground fault
circuit interrupter (GFCI) as required by NEC Arcle 680-42/USA.
7. To gain access to the swim spa’s power terminal block, pull the boom of the door panel
to break the magnec lock of the door to the frame. Place the door panel in a safe
locaon to prevent damage.
8. Select the power supply entrance you want to use, Figure A. Make sure to install a 3/4
electrical fing and conduit through the large opening provided in the side of the
control box so you can feed the cable through to the terminal block.
9. Connect wires to the terminal block (Figures B-C). ALL WIRES MUST BE SECURELY
CONNECTED or equipment damage could result!
10. Install the door panel back into place.