16
1. The Jacuzzi® Swim Spas are class "1" appliances and therefore they must be permanently
connected, without any intermediate connecons, to the electrical system and to the
protecon system (earth system)."
2. The power supplied to this swim spa must be a dedicated circuit with no other
appliances or lights sharing the power provided by the circuit.
3. The installer must use cables with a suitable cross-secon.
4. For connecon to the power supply network, we recommend installing an isolang
mul-pole switch, which will ensure complete disconnecon in the event of a
category III over-voltage; these devices must be posioned in an area that complies with
the safety regulaons.
5. The electrical system of the building must be provided with a 0.03A differenal switch
and with an efficient protecon (earth) circuit. Check for proper operaon of the
differenal switch by pressing the TEST buon, which should trip.
6. The electrical circuit supplied for the swim spa must include a suitable ground fault
circuit interrupter (GFCI) as required by NEC Arcle 680-42/USA.
7. To gain access to the swim spa’s power terminal block, pull the boom of the door panel
to break the magnec lock of the door to the frame. Place the door panel in a safe
locaon to prevent damage.
8. Select the power supply entrance you want to use, Figure A. Make sure to install a 3/4”
electrical fing and conduit through the large opening provided in the side of the
control box so you can feed the cable through to the terminal block.
9. Connect wires to the terminal block (Figures B-C). ALL WIRES MUST BE SECURELY
CONNECTED or equipment damage could result!
10. Install the door panel back into place.