TOPSIDE PANEL DISPLAY MESSAGES CONTINUED
/
Inadequate water detected in heater chamber -
Check water level in swim spa and add if
necessary. If water level is okay, make sure that
pumps are primed and all gate valves are fully
opened. Press any topside panel pad to reset.
/
Inadequate water detected in heater chamber –
displays on third occurrence of a “dr” message
within a 24 hour period. The spa shuts down
completely when the DRY message is flashing on
the display. Check water level in spa and add if
necessary, also ensure the filter is clean. If water
level is okay, make sure that pumps are primed
and all gate valves are fully opened. Press any
topside panel pad to reset.
RUN PMPS PURG AIR
Priming mode – occurs when spa is first powered
up, or when power has been restored aer a
power interrupon. Allows for safe priming of the
pumps.
- - - / - - F / - - C
Temperature unknown – aer the pump has been
operang for 2 minutes, the current water
temperature will be displayed.
- - - - -
Temperature is not current as the pump may have
been off for several hours in between filter cycles.
To view the current spa water temperature, either
switch to Ready mode or turn on the pump for at
least 2 minutes.
HOLD
Stops the control system from operang
automacally to allow filter cartridge removal.
READY
System is operang in READY mode.
REST
System is operang in REST mode.
COOL
If spa water temperature is more than 7°C (20°F)
cooler than the set temperature, the system will
automacally acvate the heater to provide
freeze protecon. This is a normal funcon; no
correcve acon is necessary.