58
10. Cool Warning: Swim spa water is more than 20
o
F / 11
o
C cooler than the temperature set
point , the circulaon pump and heater will automacally acvate to provide freeze
protecon. The swim spa will stay in this mode unl the water temperature reaches
14
o
F / 8
o
C below the set temperature. No correcve acon is necessary.
Note: The heater icon will be blinking and the error icon will be displayed under the
temperature.
11. Freeze protecon: A potenal freeze condion has been detected. No acon is required.
Jet pump(s) operate unl the swim spa is out of danger. No correcve acon is
necessary. If condion persists, contact your authorized dealer or service organizaon.
12. Overheat protecon: DO NOT ENTER THE WATER! Water temperature is above
acceptable limits. Heater is deacvated. Remove swim spa cover to speed cooling. If
condion persists, contact your authorized dealer or service organizaon.
Note:
As a safety measure, the red lights of the swim spa will flash on and off as an
indicaon that the swim spa is in an overheat condion.
The heater icon will be blinking and the error icon will be displayed under the
temperature.
WARNING: RISK OF HYPERTHERMIA (OVERHEATING) CAUSING SEVERE
INJURY, BURNS OR WELTS.
13. Controller Overheat Protecon: Controller temperature has exceeded acceptable limits.
If condion persists, provide shade for equipment side of swim spa. Contact your
authorized dealer or service organizaon.
Note: The heater icon will be blinking and the error icon will be displayed under the
temperature.
14. Panel Com Error: The topside controller is having trouble communicang to your swim
spa. Contact your authorized dealer or service organizaon.
15. CLEARRAY® Bulb Replacement Reminder: This message will appear when the
CLEARRAY® bulb reminder me has expired. The CLEARRAY® bulb must be replaced.
16. Clean Filter Reminder: This message will appear when the filter reminder me has
expired. Remove the filters for cleaning or replacement.
17. Water Refresh Reminder: This message will appear when the “Water Refresh” mer has
expired. The water needs to be drained and refilled with fresh water.