JADEVER SCALE CO., LTD
7) Press numeric key
7
to set buzz sounds. Options are Un,In,no,Lo and nbEEP.
=
There will be a warning sound when the quantity of the articles exceeds upper limit.
=
There will be a warning sound when the quantity of the articles is between the upper and
lower limit (including the upper and lower limits).
= There will be a warning sound when the quantity of the material exceeds the upper and
lower limits, and the weight of the material is more than 20 divisions.
= There will be a warning sound when the quantity of material is less than the preset lower
limit and the weight of the material is more than 20 divisions.
= No sound alarm.
8) Press numeric key
8
to select whether to save previously quantity checking values.
.
=
Previously set quantity checking values are not retained when the unit is turned on.
. = Previously set quantity checking values are retained when the unit is turned on.
9) Press numeric key
9
to shift print modes. Options are Prt.Pr, Prt.Co and Prt.St. If Prt.Co
is chosen as the print mode, PC will be automatically selected as the external devices. If
printer
is selected as the external device, please set the print modes as Prt.Pr or Prt.St.
. = manual print
. = continuous print
. = Stable printing (the weight of weighted articles should be more than 9 divisions.
Weighted articles should be removed and the scale goes back to zero before print out the next
record.)
10) Press key MC/CK to select external devices. Options are AH,TDP, ZEBRA,TP,SH,EZ and
PC.
11) Press MR to switch On or OFF RTC function.
12) When setting is completed, press key ZERO to save and return to weighing mode.
14 JCL Service Manual