The "Dead man" safety function deactivates the UDE transmitter (radio transmission cut off)
when the pushbuttons (BPSV, BPDV or "On/Horn") have not been actuated for a duration of
N minutes or seconds.
The N parameter is user-configurable and can take the values 01 to 98 minutes
On delivery, the duration is defined for 4 minutes.
- If the N value configured is 99 minutes, the transmitter considers that the dead man duration
is infinite (until the battery pack is entirely discharged).
Restarting the transmitter after the "Dead man" function has been activated:
- Press the stop palmswitch button on the transmitter.
- Follow startup procedure in §4.2
Changing the dead man duration :
The dead man duration or unit N can be modified by a trained operator by performing the
procedure described in § 3.5.3.
NB : Rotary switches COM2, COM3, COM3R and BPTR do not act on the "Dead man"
function The manipulation of these types of buttons does not rearm the temporization).
If the operator has to use switches during a long period, the temporization must be
lengthened or removed by programming, or the operator will have to rearm the
temporization by pressing regularly on the "On/Horn" button or another pushbutton
type.
5.4.3- "Dead man" function

Table of Contents

Other manuals for Jay electronique UC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jay electronique UC Series and is the answer not in the manual?

Jay electronique UC Series Specifications

General IconGeneral
BrandJay electronique
ModelUC Series
CategoryRemote Control
LanguageEnglish

Related product manuals