31
How to Set the Laser Status of the Cassette
COMMAND :SOURce:STATe
DESCRIPTION Set the laser to one of the following states:
Active. The laser driver is enabled.
Inactive. The laser driver is disabled.
When system is powered up or reset, laser is in inactive state.
NOTE: Setting the laser active does not guarantee a signal output. See
the Safety Interlock and Remote Interlock Truth Table
in interlock
section. For an illustration of the interaction between the laser driver,
and the system interlock line.
INPUT FORMAT :SOURce:STATe <C>,<S>,<D>,<State>
INPUT RANGE <State>
Boolean 0 – Inactive
1 – Active
OUTPUT FORMAT None
OUTPUT RANGE N/A
DEFAULT 0
EXAMPLE The following example activates the laser source on chassis 2, slot 8,
device 1.
Terminal Input: :SOUR:STAT 2,8,1,1
ERRORS
Error Number Error Description
-224
Illegal parameter value (out of range).
-500
Invalid address or no card inserted.