34
Local Interface
The display of the controller cassette while in manual mode is shown in Figure 10 and
described in Table 8.
Page 1:
Chassis 1 Slot 1 Device 1/1
Optical Amplifier
Input Power: 2.463 dBm
Output Power: 18.617 dBm
Mode: Const Current
Laser Status: Enabled
Laser Current: 25%
ALS Monitor: Enabled
Page->
System Exit
Page 2:
Chassis 1 Slot 1 Device 1/1
Optical Amplifier
LOS Limit: -40 dBm
BACREF Monitor: N/A
BACREF Limit: N/A
Status Register
Status Register
Page->
System Exit
Figure 10: Local Interface for MAP EDFA Page 1 and 2
Using the Controller Cassette Key Pad
Press W or X to highlight the desired “OA” chassis from the main menu
Press T to activate controls on EDFA Module
Press ▼ or▲ to toggle through functions
Press Enter ( Q ) to take control of function and enter adjust mode
Press W or X to adjust values. By depressing and holding key values can be toggled quickly
Press ‘Enter ( Q ) to store new value and escape adjust mode
Highlight and press “Exit” to release control of EDFA cassette