PAGE 32 of 54
Table 2
AUX switched to Off position or throttle stick and throttle trim moved to the
minimum position.
Turbine running over temperature. Exceeded high temperature parameter
and time out.
Turbine did not ignite within programmed time interval.
Turbine achieved ignition, but did not accelerate within programmed time
interval.
Turbine achieved ignition, but acceleration was less than the programmed
value, during startup.
Turbine exceeded the maximum RPM, by 5% and a delay of 0.5 seconds.
Turbine running under the minimum RPM, by 10% and a delay of 3 seconds.
Usually triggered by a flame out.
Battery pack is dead. Cell voltage is < 1.0V.
Turbine shut down via the AutoOff sequence, using the AUX channel.
EGT dropped below the minimum value. A dislodged EGT sensor can trigger
this shut down.
EGT exceeded the maximum range (~950 °C).
Defective kero/glow plug.
ECU processor was locked out usually from static discharge or voltage spike
in power supply.
Turbine was shut down from a failsafe timeout condition.
Turbine was shut off by using the GSU.
The power failed to the ECU when the turbine was running. This will occur if
the power was lost because of a defective battery, connection or if the switch
is turned off before the engine is shut-down.
Note: If this state is displayed the Info, Min/Max and Statistics menus
retain information from the previous run.
EGT sensor failed.
Note: This could happen only during startup.
Wrong pump type, see pump configuration in the advanced section of the
manual.
There is either no pump connected or the pump cable is defective.
The electrical current to the engine is too high.
Starter may be jammed
Kero/glow plug is short circuited