SM-18003
5-21
EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
No. Items Optional Function
Individual
Setting
Setting
Condition
Contents
100 L8 Not Prepared - - NotUsed(Useas00conditions)
101 L9 Not Prepared - - NotUsed(Useas00conditions)
102 LA Not Prepared - - NotUsed(Useas00conditions)
103 Lb Not Prepared - - NotUsed(Useas00conditions)
104 P1 SettingTemperature
×
00
01
Every1
o
F (0.5
o
C)
Every2
o
F (1
o
C)
105 P2 Not Prepared - - NotUsed(Useas00conditions)
106 P3 ThermistorSelection
×
00
01
02
03
InletAirThermistor
OutletAirThermistor
ThermistorofWiredController
RemoteSensor
107 P4 DisplayofThermistorTemperature
×
00
01
NotAvailable
Available
108 P5
SettingTemperatureDisplayduring
Fan Operation
×
00
01
Displayed
Undisplayed
109 P6 ECOButtonOperation
×
00
01
Available
NotAvailable
110 P7 Menu Button Operation
×
00
01
NotAvailable
Available
111 P8 Not Prepared - - NotUsed(Useas00conditions)
112 P9 Not Prepared - - NotUsed(Useas00conditions)
113 PA Not Prepared - - NotUsed(Useas00conditions)
114 Pb Not Prepared - - NotUsed(Useas00conditions)
115 PC Not Prepared - - NotUsed(Useas00conditions)
116 q1 Not Prepared - - NotUsed(Useas00conditions)
117 q2 Not Prepared - - NotUsed(Useas00conditions)
118 q3 Not Prepared - - NotUsed(Useas00conditions)
119 q4 Not Prepared - - NotUsed(Useas00conditions)
120 q5 Not Prepared - - NotUsed(Useas00conditions)
121 q6 Not Prepared - - Not Used
122 q7 Not Prepared - - Not Used
123 q8 Not Prepared - - Not Used
124 q9 Not Prepared - - Not Used
125 qA Not Prepared - - Not Used
126 qb Not Prepared - - Not Used
127 qC Not Prepared - - Not Used
128 qd Not Prepared - - Not Used
129 r1
DualSetpoint
(forAutomaticCOOL/HEATOperation)
00
01
NotAvailable
Available
130 r2
Cooling/HeatingChangeover
Temperature
(forAutomaticCOOL/HEAT
Operation)
00
01
02
03
04
05
2
o
F (1.0
o
C)
3
o
F (1.5
o
C)
3
o
F (2.0
o
C)
4
o
F (2.5
o
C)
5
o
F (3.0
o
C)
1
o
F (0.5
o
C)
131 r3
SetbackTemperatureCompensation
(Duringcardkeyremoval,setpointis
setbacked)
00
01
02
03
04
05
06
07
08
09
10
4
o
F (2.5
o
C)
5
o
F (3.0
o
C)
6
o
F (3.5
o
C)
7
o
F (4.0
o
C)
8
o
F (4.5
o
C)
9
o
F (5.0
o
C)
10
o
F (5.5
o
C)
1
o
F (0.5
o
C)
2
o
F (1.0
o
C)
3
o
F (1.5
o
C)
3
o
F (2.0
o
C)
132 r4 Not Prepared - - Not Used

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls HICM008B21S and is the answer not in the manual?

Johnson Controls HICM008B21S Specifications

General IconGeneral
BrandJohnson Controls
ModelHICM008B21S
CategoryAir Conditioner
LanguageEnglish

Related product manuals