5-22
SM-18003
EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
NOTES:
1. Waitatleast3minutesfrominitialpowerONtochangetheoptionalsetting.
2. Whenchanging“CF”setting(“ChangeofLouverSwingAngle”),restorethepowersupplyortestthelouver
swingacoupleoftimesintheautoswingmodetovalidatethesetting.
3. Theoptionalsettingsaredifferentaccordingtotheindoorandoutdoorunitmodels.
Checktoensureiftheunithastheoptionalsettingornot.
4. Theaboveoptionalfunctionswith“X”markattheindividualsettingcanchangetheconditiononlywhen“All
Rooms”isselectedintheTestRunMenu>FunctionSelectionMenu.
5. Functionselectionitems"q1"to"S8"areavailableonlyforindoorunitsandwiredcontrollerswithnew
softwareapplied.Checktoensureiftheunithastheoptionalsettingornot.
*1): The“02”settingmaynotbeavailableaccordingtothetypeofindoorunit.
*2): Incasethatthesettemperatureischangedandthetemperatureiskeptforaspecictimesetby“F4”,it
automaticallychangestothetemperaturesetby“F5”or“F6.”(Incasethatthesettemperatureof“F5”and
“F6”isoutofrange,theupperorlowerlimittemperatureisapplied.)
*3): Applicabletofan,coolinganddryoperationmodes.
*4): Applicabletoheatingoperationmode.
*5): Operationisstoppedbypressingthe“
”(On/Off)buttonfor3seconds.
*6): Thesensorvalueat“C8”willbeindicated.Whenthethermistorforwiredcontrollerisused,theaverage
valueofthethermistorforwiredcontrollerandthethermistorforindoorinletwillbeindicated.
*7): Whentheunitisrestartedbythewiredcontroller,thetemperatureautomaticallychangestothesetting
temperatureof“F5”or“F6”.
No. Items Optional Function
Individual
Setting
Setting
Condition
Contents
133 r5 Not Prepared - - Not Used
134 r6 Not Prepared - - Not Used
135 r7 Not Prepared - - Not Used
136 r8 Not Prepared - - Not Used
137 r9 Not Prepared - - Not Used
138 rA Not Prepared - - Not Used
139 rb Not Prepared - - Not Used
140 S1 Not Prepared - - Not Used
141 S2 Not Prepared - - Not Used
142 S3 Not Prepared - - Not Used
143 S4 Not Prepared - - Not Used
144 S5 Not Prepared - - Not Used
145 S6 Not Prepared - - Not Used
146 S7 Not Prepared - - Not Used
147 S8 Not Prepared - - Not Used