Table 8: 2.5 ton cooling charging chart for XAF*36D
and JH(E,V)T*(30,36)D in upflow
Indoor wet bulb (°F) at 80°F dry bulb
57 62 67 72
Outdoor
ambient
DB (°F)
Pressure (psig) and subcooling
(°F) at liquid base valve
55 210 (10) 212 (10) 215 (11) 220 (11)
60 230 (10) 231 (10) 235 (11) 239 (11)
65 249 (10) 250 (11) 254 (11) 258 (12)
70 270 (10) 270 (11) 274 (11) 278 (12)
75 290 (11) 290 (12) 293 (11) 298 (12)
80 315 (11) 315 (12) 317 (11) 322 (12)
85 339 (12) 339 (13) 342 (12) 347 (13)
90 365 (12) 364 (13) 366 (12) 371 (13)
95 390 (13) 388 (13) 391 (13) 395 (14)
100 422 (13) 420 (13) 424 (13) 427 (14)
105 453 (14) 452 (14) 457 (14) 459 (14)
110 484 (14) 484 (14) 489 (14) 491 (14)
115 516 (14) 517 (14) 522 (15) 523 (15)
120 547 (14) 549 (14) 555 (15) 555 (15)
125 578 (14) 581 (15) 588 (15) 587 (15)
Table 9: 2.5 ton cooling charging chart for XAH*36D
and JH(E,V)T*(30,36)D in horizontal left
Indoor wet bulb (°F) at 80°F dry bulb
57 62 67 72
Outdoor
ambient
DB (°F)
Pressure (psig) and subcooling
(°F) at liquid base valve
55 214 (13) 216 (13) 219 (14) 224 (14)
60 234 (13) 235 (14) 239 (14) 243 (15)
65 254 (13) 255 (14) 259 (14) 263 (15)
70 274 (14) 275 (15) 279 (14) 283 (15)
75 295 (14) 295 (15) 298 (14) 303 (15)
80 320 (15) 320 (16) 323 (15) 328 (16)
85 346 (15) 346 (16) 348 (15) 353 (16)
90 371 (16) 370 (16) 373 (16) 378 (17)
95 397 (16) 395 (16) 398 (16) 402 (17)
100 429 (17) 428 (17) 432 (17) 435 (17)
105 461 (17) 460 (17) 465 (17) 467 (17)
110 493 (17) 493 (17) 498 (18) 500 (18)
115 525 (17) 526 (17) 531 (18) 532 (18)
120 557 (17) 559 (18) 565 (19) 565 (18)
125 588 (17) 591 (18) 599 (19) 597 (18)
Table 10: 2.5 ton cooling charging chart for
XA(F,H)*36D and JH(E,V)T*(30,36)D in downflow and
horizontal right
Indoor wet bulb (°F) at 80°F dry bulb
57 62 67 72
Outdoor
ambient
DB (°F)
Pressure (psig) and subcooling
(°F) at liquid base valve
55 198 (5) 200 (5) 203 (6) 208 (6)
60 217 (5) 219 (6) 222 (6) 226 (6)
65 236 (5) 237 (6) 241 (6) 244 (6)
70 255 (6) 255 (6) 259 (6) 263 (6)
75 274 (6) 274 (6) 277 (6) 282 (6)
80 298 (6) 298 (7) 300 (6) 305 (7)
85 321 (6) 321 (7) 323 (6) 328 (7)
90 345 (7) 344 (7) 347 (7) 351 (7)
95 369 (7) 367 (7) 371 (7) 374 (8)
100 399 (7) 397 (7) 401 (7) 404 (8)
105 428 (8) 428 (8) 432 (8) 434 (8)
110 458 (8) 458 (8) 463 (8) 464 (8)
115 488 (8) 489 (8) 494 (8) 495 (8)
120 517 (8) 519 (8) 525 (8) 525 (8)
125 546 (8) 549 (8) 556 (9) 555 (8)
Table 11: 3 ton cooling charging chart for XAF*36D and
JH(E,V)T*36D in upflow
Indoor wet bulb (°F) at 80°F dry bulb
57 62 67 72
Outdoor
ambient
DB (°F)
Pressure (psig) and subcooling
(°F) at liquid base valve
55 203 (12) 206 (13) 208 (14) 212 (14)
60 223 (12) 226 (13) 228 (14) 232 (14)
65 242 (13) 245 (14) 247 (14) 251 (14)
70 261 (13) 265 (14) 266 (14) 271 (14)
75 280 (13) 284 (14) 285 (14) 290 (14)
80 306 (13) 309 (14) 310 (14) 315 (14)
85 331 (14) 333 (15) 335 (15) 339 (15)
90 356 (14) 358 (15) 360 (15) 364 (15)
95 381 (15) 383 (15) 385 (15) 389 (16)
100 413 (15) 415 (15) 418 (15) 421 (16)
105 445 (15) 447 (16) 450 (16) 453 (16)
110 478 (15) 479 (16) 482 (16) 485 (16)
115 510 (16) 511 (17) 514 (17) 517 (17)
120 542 (16) 543 (17) 547 (17) 550 (17)
125 574 (17) 575 (17) 579 (18) 582 (18)
R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series 17
Johnson Controls Ducted Systems

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls RHP143 Series and is the answer not in the manual?

Johnson Controls RHP143 Series Specifications

General IconGeneral
BrandJohnson Controls
ModelRHP143 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals