Table 16: ZY04 to 12 High Static Indoor Blower - With Powered Convenience Outlet (with VFD)
Compressor 1 Compressor 2
Electric Heat Field
Installed Kit 2EK045*
4
Min Disconnect Rating
Min Disconnect Rating/ Pwr Exh
Size (Tons)
Nominal Unit Voltage
RLA LRA MCC RLA LRA MCC
OD Fan Motors (each)
Supply Blower Motor
Pwr Exh Motor
Pwr Conv Outlet
Model kW Stages Amps
1
MCA (Amps)
2,3
Min Fuse/ Breaker Size (Amps)
Max Fuse/ Breaker Size (Amps)
FLA LRA
MCA w/Pwr Exh (Amps)
Min Fuse/ Breaker Size w/ Pwr Exh (Amps)
Max Fuse/ Breaker Size w/ Pwr Exh (Amps)
FLA LRA
With VFD
None - - - 40.8 45 50 42 222 43 45 50 44 227
10725 4.9 1 13.6 40.8 45 50 42 222 43 45 50 44 227
11725 12 1 33.3 59.4 60 60 55 222 62.1 70 70 57 227
208-3-60 17.6 136 27 2.3 9.9 1.1 8.6
12525 18.6 1 51.6 82.3 90 90 76 222 85 90 90 78 227
None - - - 40.3 45 50 41 231 42.3 45 50 44 236
10725 6.5 1 15.6 40.3 45 50 41 231 42.3 45 50 44 236
11725 16 1 38.5 65.3 70 70 60 231 67.8 70 70 62 236
230-3-60 17.6 136 27 2.3 9.4 1 8.6
12525 24.8 1 59.7 91.8 100 100 84 231 94.3 100 100 87 236
None - - - 20.1 25 25 21 114 21.1 25 25 22 117
10746 6 1 7.2 20.1 25 25 16 114 21.1 25 25 17 117
11746 16.5 1 19.8 33.3 35 35 31 114 34.6 35 35 32 117
460-3-60 8.5 66.1 13 1.3 4.7 0.5 8.6
12646 25.5 1 30.7 46.9 50 50 43 114 48.2 50 50 44 117
None - - - 16.1 20 20 17 102 16.9 20 20 18 104
11758 17 1 16.4 28 30 30 26 102 29 30 30 27 104
A7 (6)
575-3-60 6.3 55.3 10 1.1 4.3 0.4 8.6
12658 25.7 1 24.7 38.4 40 40 35 102 39.4 40 40 36 104
None - - - 49.4 50 60 53 262 51.6 60 60 55 272
11725 12 1 33.3 59.4 60 60 55 262 62.1 70 70 57 272
12525 18.6 1 51.6 82.3 90 90 76 262 85 90 90 78 272
13225 24 1 66.6 101 110 110 93 262 103.8 110 110 95 272
208-3-60 13.6 83.1 21 13.6 83.1 21 2.3 9.9 1.1 8.6
14225 31.8 2 88.3 128.1 150 150 118 262 130.9 150 150 120 272
None - - - 48.9 50 60 52 271 50.9 60 60 55 266
11725 16 1 38.5 65.3 70 70 60 271 67.8 70 70 62 266
12525 24.8 1 59.7 91.8 100 100 84 271 94.3 100 100 87 266
13225 32 1 77 113.4 125 125 104 271 115.9 125 125 107 266
230-3-60 13.6 83.1 21 13.6 83.1 21 2.3 9.4 1 8.6
14225 42.4 2 102 144.6 150 150 133 271 147.1 150 150 135 266
None - - - 23.2 25 25 25 136 24.2 25 25 26 132
11746 16.5 1 19.8 33.3 35 35 31 136 34.6 35 35 32 132
12846 27.8 1 33.4 50.3 60 60 46 136 51.6 60 60 47 132
13346 33 1 39.7 58.2 60 60 54 136 59.4 60 60 55 132
460-3-60 6.1 41 10 6.1 41 10 1.3 4.7 0.5 8.6
14246 41.7 2 50.2 71.3 80 80 66 136 72.6 80 80 67 132
None - - - 17.7 20 20 19 117 18.5 20 20 20 114
11758 17 1 16.4 28 30 30 26 117 29 30 30 27 114
08 (7.5)
575-3-60 4.2 33 7 4.2 33 7 1.1 4.3 0.4 8.6
13458 34 1 32.7 48.4 50 50 45 117 49.4 50 50 45 114
INSTALLATION MANUAL ZY SERIES 3-10ton 60 Hertz R-410A 61
Johnson Controls Ducted Systems

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls ZY Series and is the answer not in the manual?

Johnson Controls ZY Series Specifications

General IconGeneral
BrandJohnson Controls
ModelZY Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals