4. Cabling
JCY-1800/1850 VDR/S-VDR Installation Guide
65
DOC No. 7ZPJD0387C
Connection table: Video input CH2
RCU
Connector #
RADAR set
Connection #
Signal Name
RGB
Connector panel
J106 [R]
R Red signal
J107 [G]
G Green signal
J108 [B]
B Blue signal
J109 [H]
Hs Horizontal sync pulse
J110 [V]
Vs Vertical sync pulse
Cable Specification
Coaxial cable of 75-ohm impedance
e.g. 3C-2V / RG-59/U
4.2.6.1. Signal format of RADAR video
The video output format for a color raster scan display employs the five different signal types:
Signal Name Details of signal
R RED The red intensity amplitude.
The standard voltage level is 0.7V peak.
Impedance is 75-ohm.
G GREEN The green intensity amplitude.
The standard voltage level is 0.7V peak.
Impedance is 75-ohm.
B BLUE The blue intensity amplitude.
The standard voltage level is 0.7V peak.
Impedance is 75-ohm.
Hs HORIZONTAL Sync Synchronized signals of the horizontal line (positive/negative),
Signal is in TTL level.
Vs VERTICAL Sync Synchronized signals of the vertical line (positive/negative),
Signal is in TTL level.