6-6
2 Technical Specification
Mechanical specification
Hei
ht: 500 mm + 60 mm under the cabinet for cable
lands
Width: 500 mm
Depth: 211.5 mm
Wei
ht: 19.7 k
Electrical specification
Power intake: 1 100 VAC / 220–230 VAC +/-10% 50-60 Hz
Power
consumption:
150 VA Maximum, typically 15 VA with 3 pcs SD4 connected
or t
picall
50 VA with a ESD2 and 3 pcs SD4 connected
Display power
output terminals:
9 12..28 VDC-outputs distributed over three fuses:
3 x 1A. Maximum total output load 3A
ESD power output: 1 18..32 VDC outputs distributed over one fuse. 1+2 spare terminals
Maximum total output load: 1.5A
Serial inputs: 9 Standard IEC61162-1 / NMEA0183
Analo
ue inputs: 1 +/-10 V
Opto inputs: 4 Digital inputs that can detect a voltage above
3.5 V, maximum volta
e 40 VDC
Serial output
terminals:
23 IEC61162-1 / NMEA0183, totally 13 drivers
(Divided into 8 channels)
Serial terminal: 1 RS232 For older
eneration ESD, in/out
Analo
ue outputs: 2 +/-5VDC, max load 10 mA
Switching relay
outputs:
4 Switching: 30VDC / 1A
Note! Not intended for distance pulses.
Closing relay
outputs:
4 Closing: 50VDC / 0.5A
30V/30mA or 15V/100mA recommended max load when used as
distance pulse rela
s.
Opto outputs: 8 5 to 40 VDC, max 50 mA
Ethernet
connection
1 RJ45, DHCP server. Web-interface for service and set up.
USB Device 1 The USB Device slot is not used.
USB Host 2 Only the lower USB Host 1 slot is used
Service D-sub 1 RS232 for service purpose; terminal, Winflash.
Environmental specification
Enclosure material: Steel plate
Enclosure protection: IP22, splash proof
EMC: IEC 60945, protected class
Heat dissipation (max) = Power consumption
Colour: RAL 7035
Recommended operating
temperature
0°C to +40° C
Extreme operatin
temperature: -15°C to +55° C
Extreme operatin
Humidit
: Less than 93 % RH (non-condensin
) at 40°C