EasyManua.ls Logo

JRC JLN-900 - Menu Function Summary

JRC JLN-900
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-22
4.5 Menu function summary
The list is included for fast indexing. Menus in bold font are main menus.
Menus with access level “Expert” are not visible in “All Users” mode.
“Expert” menus are only for development purpose. Only instructed personnel are intended to
use these menus.
No. Access
Level
Name Default Function
R0
Root menu
Timeout to root menu after 30 seconds.
Presentation according to 4.4.1 Root Menu
A0 All Users
DIAGNOSTICS
Select menu to view log statistics since
system start up
A1 All Users
TOTAL UPTIME
Show the WATER TRACK U. system total
uptime
A2 All Users
DIAG HISTORY
Press enter to access the history
A2.1 All Users
– or + keys scroll history list
A3 All Users
ERASE HISTORY DISABLED
Erase history list
C0 All Users
CALIBRATION
Select calibration menus
C1 All Users
DRAUGHT COND FULL LOAD
Select one of three predefined draught
condition
C1.1 All Users
Set calibration factor for selected draught
condition
C3 All Users
MULTI-P CAL. ENABLED
Select Multiple Point Calibration edit/delete
C3.1 All Users
ENABLED
Select first Multiple Point pair to edit/delete
C3.11 All Users
Set speed at first point
C3.111 All Users
Set calibration value for first speed
C3.n All Users
ENABLED
Select n
th
Multiple Point pair to edit/delete
C3.n1 All Users
Set speed at n
th
point
C3.n11 All Users
Set calibration value for n
th
speed
C4 All Users
TRU CALIBRAT TC+000
Set engraved transducer calibration factor
C5 Expert
CALIBR RESET DISABLED
Reset calibration values
D0 Expert
DEBUG
Select Debug menus
D1 Expert
DATA LOGGING DISABLED
Put $PSALD in NMEA output stream
D2 Expert
SAMPLE TO ETH 239.168.1
.70
Stream binary signal data as UDP through
the Ethernet connector
M0 All Users
MISCELLANEOUS
Select miscellaneous menus
M1 Expert
SET DEFAULT DISABLED
Restore default values for all non-volatile
settings except calibration factors
M2 All Users
RESET CPU DISABLED
Reset CPU by disabling watchdog
M4 All Users
TOT. DISTANCE
Show and adjust the total distance counter
M5 All Users
TRIP DISTANCE
Reset trip counter
M6 All Users
SW revision
Display the application software revision
5400130 xxx
M7 Expert
APP revision
Display the application revision
6400331 xxx
M8 Expert
FW revision
Display the firmware revision
6400341 xxx
M9 Expert
HW revision
Display the HW revision
5490240 REV x
M10 All Users
Access level
All Users: Only menus with access
level “All Users” are
visible
Authorised Expert:
All menus are visible

Table of Contents