7-12
Access is made to the Menu system in the WT Unit. To
exit back to Local mode the Esc button shall be used.
The Esc button will always step out from the Menu
system of the remotely controlled device.
Menu and Enter pressed simultaneously is used to step
back within the remotely controlled device Menu system.
Press Esc
R1 DEVICE 1 OF 2
BTU 1 (T2A)
Press Esc (or Menu and Enter simultaneously)
R0 REMOTE DEV
CONNECT
If the Mode button is pressed while a device Menu system is accessed, a short help
text will be displayed referring to actual device presently accessed, e.g. when inside the
Menu system of the WT unit the following text will be displayed as long as the Mode
button is pressed:
REMOTE: R1A
5.3 Remote Dim set-up
It is possible to remotely control the Display brightness from another Display.
ID numbers of up to four Displays which are to be controlled can be chosen in menu
LS3. Displays with an ID that corresponds with this set-up will have the same
brightness as the Master Display. This gives possibility to have the same brightness on
up to four Displays on the bridge, without Display(s) in other locations being affected.
(More Displays can use the same ID, which makes it possible to actually dim more
than four Displays.)
The ID number of the NWW-85 Docking Display can not be changed and is by default
set to 5.
When REMOTE DIM is activated in menu LS3 the lower line of the BASIC Menu will
display REMOTE DIM [OFF].
- As long as this setting is OFF this display will not send out any remote dim
messages.
- When set to ON, remote dim messages will be sent out to other Displays when
pressing the DIM push buttons on the display or when the external inputs
are used for dimming.
- When set to EXT this Display will not send out any remote dim messages when the
push buttons on the display are used for dimming but when the external input is
used remote dim messages will be sent out.
See 6.4.2. External DIM set-up (Terminals 7 + 8) for more information.