10-23
No. Access
Level
Name Default Function
P0 Expert
PARAMETERS
Set Parameters menus
P1 Expert
Measure type Auto
Set working mode of the log.
P2 Expert
Particle mode Enabled
Enable/disable PARTICLE as one of the
toggling modes during TEST mode
P3 Expert
Particle mode
Depth
130
Desired measuring depth in PARTICLE
mode.
P4 Expert
Particle mode
Max Rx offset
2
Maximum number of simultaneously active
transmissions in PARTICLE mode
P5 Expert
Particle mode
Tx Length
28
Desired transmission length in PARTICLE
mode
P6 Expert
Speckle mode Enabled
Enable/disable SPECKLE as one of the
toggling modes during TEST
P7 Expert
Speckle mode
Depth
500
Desired measuring depth in SPECKLE
mode.
P8 Expert
Speckle mode
Max Rx
3
Maximum number of simultaneously active
transmissions in SPECKLE mode
P9 Expert
Pulse mode Enabled
Enable/disable PULSE as one of the toggling
modes during TEST
P10 Expert
Pulse mode
Max depth
130
Desired measuring depth in PULSE mode.
P11 Expert
Pulse mode
Max Rx offset
0
Maximum number of simultaneously active
transmissions in PULSE mode
P12 Expert
Dirty mode Enabled
Enable/disable DIRTY as one of the toggling
modes during TEST
P13 Expert
Dirty mode
Depth
Enabled
Desired measuring depth in DIRTY mode.
P14 Expert
Dirty mode
Max Rx offset
0
Maximum number of simultaneously active
transmissions in DIRTY mode
P15 Expert
Forced cycle
length
0
Force a constant cycle length independent of
measuring mode
P16 Expert
Median filter
length
5
Length of median filter applied to raw speed
P17 Expert
Adapt gain
factor
1,25
Maximum allowed gain in adaptive gain
filter following median filter
P18 Expert
Correlation
threshold
100
Raw speed invalid if correlation < threshold
P19 Expert
Zero speed
qual. thres
100
Raw speed invalid if quality < threshold
P20 Expert
Zero sp. ACF
threshold
250
Zero speed qualifier threshold for ACF
P21 Expert
Manual h-spd
thresh.disabl
ed
Disabled
Enable manual adjustment of threshold for
decision of mode transfer to high speed mode
P21.1 Expert
Auto
calc.
Set threshold for high speed mode transfer
P22 Expert
Layer jitter 40
Set jitter jump length in us

Table of Contents