10-24
No. Access
Level
Name Default Function
S0 All Users
SETTINGS
Select Settings menus
S1 All Users
Average Low 10
Set averaging time constant in seconds for
low speed range
S2 All Users
Threshold
Low-Hi
3.0
Speed limit between low and high averaging
time constant.
S3 All Users
Average High 10
Set averaging time constant in seconds for
high speed range
S6 All Users
Lock Timeout 20
Timeout before speed is set invalid after
speed loss [sec]
S7 Expert
NMEA Interval 1.0
NMEA message interval [sec]
S9 All Users
VBW Telegram Extended
Control $VDVBW telegram format
S10 All Users
VHW Telegram Disabled
Add telegram $VDVHW to NMEA stream
S11 Expert
LogFail-Alrm Power-
Fail
Set Log Fail Alarm relay to power fail or
invalid speed
S12 All Users
Analog Speed Ahead +
Astern
T0 All Users
TEST
Selects Test menus
T1 All Users
Simulation Disabled
Enable simulated speed as $VDVBW in
NMEA output stream
T1.1 All Users
Simulation 8.00
Adjust simulated speed if desired
T2 All Users
Noise test Disabled
Enable forced execution of noise level test
T2.1 All Users
Noise level
View result of forced noise level test
T3 All Users
TRU S balance Disabled
Enable forced execution of transducer signal
balance test
T3.1 All Users
Sig Balance
View result of forced signal balance test
T4 All Users
Loop test Disabled
Enable forced execution of loop test
T4.1 All Users
Loop test
View result of forced loop test
T5 All Users
Force test Disabled
Enable forced execution of all self-diagnosis
tests
T5.1 All Users
Code
View diagnostic codes resulting from the
forced self-diagnosis
T6 All Users
LogFail Alarm Disabled
Enable forced switching of LFA relay
T6.1 All Users
LFA Relay
Activate relay switching
V0 All Users
VIEW
Select menu to view log statistics since last
power up
V1 All Users
System Uptime
Read uptime since last power on
V2 All Users
Noise levels
Read highest noise levels, last sequence
V3 All Users
TRU S balance
Read most unbalanced signal last sequence
V4 All Users
Loop test
Read average loop test result last sequence

Table of Contents