6-13
NMEA out 10 – 15, connections to NMEA slave displays NWW-82/85
Provisions are made to connect NMEA output and DC power to slave displays. In total,
including the Speed log master display, a maximum of 9 (nine) displays can be powered from
the Sig. Distributor.
Term# Function Note
45A NMEA out 10 Connect to NWW-82/85 NMEA "A" input
45B NMEA out 10 Connect to NWW-82/85 NMEA "B" input
52+ +12 to 28 VDC Connect to DC power input of displa
y
. Fuse F301
52- 0 VDC Connect to DC power input of displa
y
Term# Function Note
46A NMEA out 11 Connect to NWW-82/85 NMEA "A" input
46B NMEA out 11 Connect to NWW-82/85 NMEA "B" input
53+ +12 to 28 VDC Connect to DC power input of displa
y
. Fuse 302
53- 0 VDC Connect to DC power input of displa
y
Term# Function Note
59A NMEA out 12 Connect to NWW-82/85 NMEA "A" input
59B NMEA out 12 Connect to NWW-82/85 NMEA "B" input
54+ +12 to 28 VDC Connect to DC power input of displa
y
. Fuse F302
54- 0 VDC Connect to DC power input of displa
y
Term# Function Note
60A NMEA out 13 Connect to NWW-82/85 NMEA "A" input
60B NMEA out 13 Connect to NWW-82/85 NMEA "B" input
55+ +12 to 28 VDC Connect to DC power input of displa
y
. Fuse F302
55- 0 VDC Connect to DC power input of displa
y
Term# Function Note
61A NMEA out 14 Connect to NWW-82/85 NMEA "A" input
61B NMEA out 14 Connect to NWW-82/85 NMEA "B" input
56+ +12 to 28 VDC Connect to DC power input of displa
y
. Fuse F303
56- 0 VDC Connect to DC power input of displa
y
Term# Function Note
62A NMEA out 15 Connect to NWW-82/85 NMEA "A" input
62B NMEA out 15 Connect to NWW-82/85 NMEA "B" input
57+ +12 to 28 VDC Connect to DC power input of displa
y
. Fuse F303
57- 0 VDC Connect to DC power input of displa
y
Term# Function Note
58+ +12 to 28 VDC Connect to DC power input of displa
y
58- 0 VDC Connect to DC power input of displa
y
. Spare terminal. Fuse F303
The NMEA out A and B shall be connected to the NMEA in connections of the SD4 displays
via a twisted pair cable. It is recommended to use a shielded cable with two twisted pairs to
connect the slave SD displays to the Sig. Distributor, one pair for NMEA and one pair for
power.