7-15
No. Name Default setting Function
SD
4-2
SD
4-3
SD
4-4
LP2.21 DIAGNOSTICS
OFF OFF OFF
Display diagnostic codes
(PSALW)
LP2.22 DOCKINGLOG
OFF OFF OFF
SOG transversal of the BOW and
STERN
LP2.23 STANDBY STW
OFF OFF OFF
Deactivates valid STW NMEA to
invalid STW NMEA
LP3 STARTUP DIM
[50%]
50% 50% 50%
Default brightness after a reset
LP4 NEG SPD USE
[OFF]
OFF OFF OFF
Longitudinal distance counters
and pulse output off at negative
speed
LP5 LP5 EXT INPUT
[DIM]
DIM DIM DIM
Sets function of external inputs.
DIM or SDR2 (Control Unit)
LP6 LP6 EXT OUTPUT
[200 P/NM STW-L]
STW
-L
STW
-L
STW
-L
Sets function of external output:
200 P/NM STW-L
200 P/NM SOG-L
LP7 NMEA GATE
THROUGH [OFF]
OFF OFF OFF
NOTE. Always OFF when
connected back to the Log system,
(Can be used if more displays are
connected in series)
LP8 NMEABAUDRATE
[4800]
4800 /38400
NOTE. Do not change.
LP9 PREFERRED
DEPTH [AUTO]
AUTO AUTO AUTO
[AUTO] (KEEL/SENSOR/SURFACE)
Displays most shallow depth if
SDDPT with different offset is
received.
[SURFACE] If both + and -
offset, displays SURFACE depth
[SENSOR] Only displays
SENSOR depth
LPA AUTO STW
WHEN NO SOG[ON]
ON ON ON
Speed windows switch to STW
when SOG out of range.
LPB SPEED VALUE
2 DECIMALS [OFF]
OFF OFF OFF
Displays speed values with two
decimals, when enough space.
LPC SW REVISION
704021xx
704021xx for SD4-2 (Main
Display), -3
704024xx for SD4-4
LPD RESET TOTAL
LOCAL DISTANCE
LPD.01 RESET TOT
CONFIRM [NO]
NO NO NO
Resets all total distance counters
in the display to 0.
LPE
SET DEFAULT
MENU PARAMETERS
LPE.01 RESET MEN
CONFIRM [NO]
NO NO NO
Sets all menu parameters in the
Display to default value.
(Depending on type of Display)

Table of Contents