10-20
middle value lie in the interval 40 – 120. The middle value
shall be stable during the test. The value depends on
transducer load.
T5 RUN SELFTESTS
DISABLED
Menu T5 forces all built-in self-diagnostic tests to be executed. The A2 DIAG
HISTORY list is cleared at start of test. If any self-test fails a diagnostic code
will be activated.
Use + to change menu to ENABLED and then Enter to start the test and go to
next sub-level where the test result will be displayed.
T5.1 NO CODES
IN LIST
Menu T5.1 will continuously show the latest generated
diagnostic code. The list will be cleared upon entering this
menu. Any new code activated as a result of the forced test
(it can take several seconds) will be shown in the order of
appearance.
T6 LOGFAIL ALARM
DISABLED
Menu T6 forces the log fail alarm relay to be set from this menu instead of
internal status.
Use + to change menu to ENABLED and then Enter to start the test and go to
next sub-level where the relay can be toggled.
T6.1 LFA RELAY
NO ALARM POS.
Menu T6.1 displays the present LFA relay position.
NO ALARM POS. (if relay is not in alarm position) or
ALARM POSITION (if relay is in alarm position)
Use – or + to select desired relay position and then Enter to
physically set the relay.
4.4.8 Menu V, View menus
End user and service personnel are intended to use these menus to gather statistics.
Press Enter to go into sub-menus. All menus are read only. To interpret the values please refer
to corresponding T menus.
V0 VIEW RECORDED
WRITE ACCESS OFF