4-16
Transducer and Valve Cover Assembling
The Assembly consists of:
x Transducer with cable (30/40 m)
x Valve Cover with:
- Connecting Tube with sealing items.
- Tube Bracket with mounting items.
Assemble as follows:
1. The Valve Cover shall not yet be mounted on the Sea Valve.
x Check that the two Lip Seals are correctly mounted inside the top end of the
Valve Cover. Normally mounted from factory.
x Assure Lip Seals to be clean and free from particles/dirt.
x Slightly lubricate the Lip Seals with Vaseline®, Silicone grease or similar.
2. Mount the Cable Gland on the Connecting Tube.
Cable Gland mounted
3. Gently push the Connecting Tube through the Valve Cover top end.
Note: It is important that the Connecting Tube is inserted from top end of the Valve
Cover. Never try to insert the opposite way, will damage the Lip Seals.
Connecting Tube inserted