Section 3 Common Basic Operations 3-22
3.13.2 Displaying the EBL and VRM buttons
Use the EBL/VRM button for creation and setting of EBL/VRM and bearing/range of EBL/VRM.
The EBL/VRM button is always displayed on measuring tools at the upper right corner of the screen.
The display mode of EBL/VRM that is displayed on the dialogue by selecting [View] - [Tools] on the
menu can be set to display/hide.
3.13.3 Basic manipulation of EBL/VRM
3.13.3.1 Switching the control right of EBL/VRM
This equipment is equipped with two sets of EBL (EBL1/EBL2) and VRM (VRM1/VRM2).
To use EBL/VRM, the EBL/VRM to be used must be enabled.
To enable EBL/VRM, click on the EBL/VRM button.
The status of EBL/VRM can be checked by using the EBL/VRM button.
[Button in [Off] state]
EBL/VRM is disabled and is not displayed on the screen.
When the button is clicked on, EBL/VRM is displayed and the manipulation is enabled.
[Numeric value displayed on the button]
• When the button is enclosed by a blue frame, EBL/VRM is displayed and the manipulation is
enabled (with control right).
When this button is clicked on, the blue frame is cleared and the manipulation is disabled (without
control right).
• When the button is not enclosed by a blue frame, although EBL/VRM is displayed on the screen,
the manipulation is disabled (without control right).
When the button is clicked on, the display is changed to [OFF].
When the button is double-clicked, the button is enclosed by a blue frame and the manipulation is
enabled (with control right).
EBL button (Left: EBL1, Right: EBL2)
VRM button (Left: VRM1, Right: VRM2)