4-23 Section 4 Range and Bearing Measurement Methods
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
1
4.6.6 Displaying two intersecting lines (Equiangular
mode)
When the operation mode is set to [Equiangular], two intersecting lines are displayed.
1 Select [Equiangular] from the [Mode] combo box.
2 Select a parallel index line group (1 to 4) from the [Group].
Since parallel index lines form pairs in [Equiangular] mode, set in group units.
3 Select [Display].
The selected parallel line cursor group is displayed.
4 Enter the bearing of the parallel index line group in [PI Bearing] (parallel index line
bearing adjustment).
Memo
The bearing can also be adjusted by turning the [EBL] dial clockwise/counterclockwise.
When the dial is turned clockwise, the bearing is adjusted in the plus direction, and when
the dial is turned counterclockwise, the bearing is adjusted in the minus direction.
The set value is displayed in the input box.
5 Enter the vertical angle of the parallel index line group in [Vertical Angle] (vertical
angle).
Display Example