14-15
Section 14 Adjusting and Setting up Equipment (for Services)
1
14
Setting Item
Description of Setting
Setting Value
Scanner Unit1 to 8
(equipment
positions of radar
antennas 1 to 8)
Enter the equipment positions of Radar Antennas 1 to 8
in the boxes.
X: Horizontal axis position of radar antennas 1 to 8 on
the ship (Centre: 0)
Y: Front-back axis position of radar antennas 1 to 8 on
the ship (Stern: 0)
Memo
If "No Equipment" is specified in the [DipSW] settings
of the interswitch unit, this is not displayed.
When the input range is changed by modifying
[Length] and [Beam], if a value exceeding the input
range after modifying has already been entered, the
value will be corrected to the maximum or minimum
value.
Varies depending on the
values set in [Length] and
[Beam].
When Length =a Beam =b:
X -b/2 to b/2
Y 0.0 to a
For instance,
When Length =1.0 Beam
=1.0
X -0.5 to 0.5
Y 0.0 to 1.0
When Length =700.0 Beam
=70.0
X -35.0 to 35.0
Y 0.0 to 700.0
CCRP1/2/3/4
Enter the positions of CCRP1 to CCRP4 of the ship in
the boxes.
X: Horizontal axis position of CCRP1/2/3/4 on the ship
(Centre: 0)
Y: Front-back axis position of CCRP1/2/3/4 on the ship
(Stern: 0)
Memo
When the input range is changed by modifying [Length]
and [Beam], if a value exceeding the input range after
modifying has already been entered, the value will be
corrected to the maximum or minimum value.
Radio button on
the left side of
each CCRP
Select the position to be used as the ship's CCRP by
clicking on the applicable button.
CCRP1
CCRP2
CCRP3
CCRP4