3 Remove the cable.
Loosen four screws (M4×12).
Slide the cover to the left, and then remove
it.
Remove one connector of the encoder.
(J209)
Remove five connectors of the installed
cable.
(J1 to J5)
Remove two connectors of the safety
switch.
(J210 and J1504)
Remove two connectors of the motor.
(J1502 and J125)
Remove 10 connectors in total.
Remove one screw (M4×10) and remove