3-3 
3
 
Table 3.1.1 The status of MES which LED lamps indicated 
(Number of the button name corresponds to Figure 2.3.2a) 
NAME ON  OFF 
(2)  POWER Lamp  MES power on.  MES power off. 
(3)  SYNC Lamp  Bulletin Board OK. 
When the MES is returned the NCS channel 
to the TDM channel or the TDM channel to 
the NCS channel, this LED is blinking. 
Bulletin Board NG. 
(4)  LOG-IN Lamp  Logged in.  Logged out. 
(5)  TRANSMIT Lamp  MES carrier on.  MES carrier off. 
(6)  RECEIVE Lamp  Message receiving.  No message, or message 
received and output it to DTE 
and/or Printer. 
(7) ALARM Lamp 
・When TX Alarm *
1
 is occurred, it blinks 
at intervals of 0.5 seconds. 
・When Battery Alarm*
2
 is occurred, it 
blinks with 1 second interval.   
・ When both of TX and Battery Alarms are 
occurred, this lamp lights without blink. 
・ Security alert is not transmitted even if 
the button is pushed, when the bad 
connection cannot be recognized. 
Normal condition. 
 
(To extinction the lamp, 
turn on and off the power 
switch.) 
 
*1) TX Alarm informs some sort of malfunction is occurred on communication devices. 
*2) Battery Alarm informs the battery is decreased to under the specified level. 
 
Table 3.1.2 Function of switch and buttons 
 
Name Function  Remarks 
(1)  POWER Switch  Power ON/OFF the MES.   
(8) RESET Button  To reset the status of JUE-95SA 
when it operates abnormally. 
Refer to 4.6 of this manual and be 
careful to handle this button. 
(It seems as a very little hole.    Press 
the switch exists in the hole with 
narrow object like a wire.) 
(9)  TEST Button  To use for SSAS test transmission.   
 
Table 3.1.3 Connectors and the Cable (Refer 2.3.2b for detail) 
 
Name Connected from/to 
EME Connector  IME to EME 
Power Supply Connector  IME to AC adopter of PSU (24V) 
DTE Connector  IME to DTE and DS/DTE 
Option Connector (X5 and X6)  IME to Security Button 1/2(X5), and Security Button 3/4(X6)