3-16
Step 3 Security Alert is kept transmitted regularly at set intervals to the address set beforehand.
Step 4 Push the button again when you want to cancel security alert transmission.
Turn off all buttons when you pushed 2 or more buttons at the time of transmission.
Security Alert transmission is not canceled as long as one button is remained turned on.
NOTE
Discontinuing transmission procedure when button is pushed by mistake
Push the Button again within 30 seconds: No transmission
Push the Button again after 30 seconds passed : Security Alert is transmitted only of first
time, and no transmission is carried out after then.
Pull out the Power cable from IME rear panel and push the button to turn to OFF, when you
want to discontinue transmitting at once regardless of the time after the button is pushed.
NOTE
The message of the following content reaches the destination when the Security Alert is
transmitted.
This is a SECURITY MESSAGE
Ship Name :ABCD
Call Sign :DFGZ
MMSI :123456789
SECURITY SECURITY
MES NO, 987654321
LAT,N12 34.56LON,E123 45.56,UTC,07.01.2004 12:34,SOG,
10.0KT,COG,20DEG
NOTE
User edit
message
(Example)
Automatic
insertion
message
Exam
le